Fire protection element D2

Fire protection element D2

Lightweight concrete slab reinforced with glass fibers bonded with cement for escape routes.

Application: For covering concrete troughs near track beds or as a replacement for wooden plank covering.

 

Specific data

CategoryValue / Description
Characteristic values
Equilibrium humidity (65% rel.)≈ 7% (at 20 °C and 65% RH, according to DIN EN ISO 12570)
Alkalinity (pH value)≈ 12
approval
Construction material classEN 13501-1 — Non-combustible, A1
Fire resistance classI 90 and E 90 (1)
Panel parameters and formats
Panel thickness52.5 mm
Surface weight per m² (with humidity 5%)47 kg/m²
Panel format1 250 × 625 mm
Other formatsThickness, formats and cuts on request
Dimensional tolerances
Width± 1mm
Thickness± 2mm
Maximum permitted traffic load
60 cm12.5 kN/m²
80 cm7.0 kN/m²
95 cm5.0 kN/m²
100 cm4.5 kN/m²
125 cm2.8 kN/m²
Maximum permissible load (jump test)
Support width100 cm
Jump height82 cm
Test subject100 kg
Investigation reportMFPA Leipzig, UB III/B-06-014
(1) Fire resistance values depend on the construction system and assembly details.